| $MODEL |
| |
+--------------------------------------------------------------------+
MEANING: Specifies the MODEL subroutine of PREDPP
CONTEXT: NM-TRAN Control Record
USAGE:
$MODEL [NCOMPARTMENTS=n1] [NEQUILIBRIUM=n2] [NPARAMETERS=n3]
[COMPARTMENT=([name] [attribute1] [attribute2] ...)] ...
[LINK compnamea [TO|AND] compnameb BY k [l]] ...
[I_SS=n]
SAMPLE:
$MODEL NPARAMETERS=3
COMP=(DEPOT DEFDOSE INITIALOFF) COMP=(CENTRAL DEFOBS NOOFF)
DISCUSSION:
Required with a general ADVAN (ADVAN5,6,7,8,9,13,14,15).
OPTIONS:
NCOMPARTMENTS=n1
Total number of compartments other than the output compartment.
Default: the number of COMPARTMENT options. May also be coded
NCM or NCOMPS.
NEQUILIBRIUM=n2
Number of equilibrium compartments. Default: 0
NPARAMETERS=n3
Number of basic PK parameters. Default: The number of basic PK
parameters defined in the $PK abbreviated code. May also be
coded NPARAMS. May be 0 with the general non-linear models
(ADVAN6, ADVAN8, ADVAN9, ADVAN13, ADVAN14, ADVAN15).
COMPARTMENT= ([name] [attribute1] [attribute2] ...)
Each COMPARTMENT option defines a single compartment. Compart-
ments are numbered in the order in which they are defined. The
name option gives the name for the compartment. The name option
may not be one of the compartment attributes below, unless it is
enclosed in quotes (' or ").
If the name option is not used, then the compartment is named
"COMPn," where n is the compartment number.
Attributes are chosen from the following list. When an attribute
is not chosen, its opposite is the default.
INITIALOFF - Compartment is initially off.
NOOFF - Compartment may not be turned on or off.
NODOSE - Compartment may not receive a dose.
EQUILIBRIUM - Compartment is an equilibrium compartment (ADVAN9
and ADVAN15 only; implies NODOSE).
EXCLUDE - Compartment amount is excluded from the computation
of the amount (Amt) of the output compartment (ADVAN9 and
ADVAN15 only). [Amt=(total amount of drug thus far input into
system) minus (total amount remaining in the system)]
The following two attributes have no opposites.
DEFOBSERVATION - Compartment is the default observation com-
partment.
DEFDOSE - Compartment is the default dose compartment.
If no compartment has the DEFOBSERVATION attribute, the default
is the first compartment with the name CENTRAL; otherwise, the
first compartment. If no compartment has the DEFDOSE
attribute, the default is the first compartment with the name
DEPOT which may receive doses; otherwise, the first compartment
which may receive doses.
LINK compname [TO|AND] compname BY k [l]
Link clauses are used with ADVAN5 and ADVAN7, but only in the
absence of $PK abbreviated code. They are rarely used, and are
described in Guide IV.
I_SS= n
I_SS may be used with the general non-linear models (ADVAN6,
ADVAN8, ADVAN9, ADVAN13, ADVAN14, ADVAN15) to request the initial
state feature of PREDPP. Values of n are
0 No initial state state (the default)
1 Initial steady state
2 Initial steady state, adds to current compartment amounts.
3 Initial steady state, use current compartment amounts as ini-
tial estimates.
The attributes INITIALOFF NODOSE define an output-type compartment.
As with the output compartment, it is possible to use a negative value
of CMT to obtain an observation and turn off such a compartment with
one observation record. Like the output compartment, it is initially
off, and it remains off (so that the amount therein remains zero)
until it is explicitly turned on by an other type event record which
has the output compartment's number in the CMT data item. Unlike the
output compartment, a differential equation (DADT) must be supplied
for an output-type compartment.
(See advan68, advan9_15, $pk)
(See Initial Steady State: I_SS,ISSMOD).
RECORD ORDER:
Follows $SUBROUTINES
Precedes $PK (if present)
REFERENCES: Guide IV Section V.C.4
REFERENCES: Guide VI Section VI.B
Go to main index.
Created by nmhelp2html v. 1.0 written by Niclas Jonsson (Modified by AJB 5/2006,11/2007,10/2012)