 |                               $MODEL                               |
 |                                                                    |
 +--------------------------------------------------------------------+

 MEANING: Specifies the MODEL subroutine of PREDPP
 CONTEXT: NM-TRAN Control Record

 USAGE:
 $MODEL   [NCOMPARTMENTS=n1] [NEQUILIBRIUM=n2] [NPARAMETERS=n3]
          [COMPARTMENT=([name] [attribute1] [attribute2] ...)] ...
          [LINK compnamea [TO|AND] compnameb BY k [l]] ...
          [I_SS=n]

 SAMPLE:
 $MODEL   NPARAMETERS=3
          COMP=(DEPOT DEFDOSE INITIALOFF) COMP=(CENTRAL DEFOBS NOOFF)

 DISCUSSION:
 Required with a general ADVAN (ADVAN5,6,7,8,9,13,14,15).

 OPTIONS:

 NCOMPARTMENTS=n1
      Total  number  of compartments other than the output compartment.
      Default: the number of COMPARTMENT options.  May  also  be  coded
      NCM or NCOMPS.

 NEQUILIBRIUM=n2
      Number of equilibrium compartments.  Default: 0

 NPARAMETERS=n3
      Number  of  basic PK parameters.  Default: The number of basic PK
      parameters defined in the $PK  abbreviated  code.   May  also  be
      coded  NPARAMS.   May  be  0  with  the general non-linear models
      (ADVAN6, ADVAN8, ADVAN9, ADVAN13, ADVAN14, ADVAN15).

 COMPARTMENT= ([name] [attribute1] [attribute2] ...)
      Each COMPARTMENT option defines a single  compartment.   Compart-
      ments  are  numbered in the order in which they are defined.  The
      name option gives the name for the compartment.  The name  option
      may  not be one of the compartment attributes below, unless it is
      enclosed in quotes (' or ").
      If the name option is not used, then  the  compartment  is  named
      "COMPn," where n is the compartment number.

      Attributes are chosen from the following list.  When an attribute
      is not chosen, its opposite is the default.

        INITIALOFF - Compartment is initially off.
        NOOFF - Compartment may not be turned on or off.
        NODOSE - Compartment may not receive a dose.
        EQUILIBRIUM - Compartment is an equilibrium compartment (ADVAN9
        and ADVAN15 only; implies NODOSE).
        EXCLUDE  -  Compartment amount is excluded from the computation
        of the amount (Amt)  of  the  output  compartment  (ADVAN9  and
        ADVAN15  only).  [Amt=(total amount of drug thus far input into
        system) minus (total amount remaining in the system)]

      The following two attributes have no opposites.

        DEFOBSERVATION - Compartment is the  default  observation  com-
        partment.
        DEFDOSE - Compartment is the default dose compartment.
        If no compartment has the DEFOBSERVATION attribute, the default
        is the first compartment with the name CENTRAL; otherwise,  the
        first   compartment.    If   no  compartment  has  the  DEFDOSE
        attribute, the default is the first compartment with  the  name
        DEPOT which may receive doses; otherwise, the first compartment
        which may receive doses.

 LINK compname [TO|AND] compname BY k [l]
      Link clauses are used with ADVAN5 and ADVAN7,  but  only  in  the
      absence  of  $PK abbreviated code.  They are rarely used, and are
      described in Guide IV.

 I_SS= n
      I_SS may be used with  the  general  non-linear  models  (ADVAN6,
      ADVAN8, ADVAN9, ADVAN13, ADVAN14, ADVAN15) to request the initial
      state feature of PREDPP.  Values of n are
        0 No initial state state (the default)
        1 Initial steady state
        2 Initial steady state, adds to current compartment amounts.
        3 Initial steady state, use current compartment amounts as ini-
        tial estimates.

 The  attributes  INITIALOFF  NODOSE define an output-type compartment.
 As with the output compartment, it is possible to use a negative value
 of  CMT  to obtain an observation and turn off such a compartment with
 one observation record. Like the output compartment, it  is  initially
 off,  and  it  remains  off  (so that the amount therein remains zero)
 until it is explicitly turned on by an other type event  record  which
 has  the  output compartment's number in the CMT data item. Unlike the
 output compartment, a differential equation (DADT)  must  be  supplied
 for an output-type compartment.

 (See advan68, advan9_15, $pk)
 (See Initial Steady State: I_SS,ISSMOD).

 RECORD ORDER:
 Follows $SUBROUTINES
 Precedes $PK (if present)

REFERENCES: Guide IV Section V.C.4
REFERENCES: Guide VI Section VI.B


  
Go to main index.
  
Created by nmhelp2html v. 1.0 written by Niclas Jonsson (Modified by AJB 5/2006,11/2007,10/2012)